Mon–Fri 9–5 ET · Nationwide crews
Server rack filled with network and computing equipment

Server Rooms & Network Infrastructure

Server Solutions

Racks, switching, storage, cooling and backup, built so the room stays cold, documented and quiet, with recovery a procedure rather than a panic.

Overview

The room that everything else reports to

Server rooms tend to accumulate rather than get designed. A switch here, a NAS on a shelf, a UPS under the desk, cable bundles nobody dares touch. It works right up until a drive fails, a breaker trips, or the AC goes out over a long weekend.

Wiscom builds and rebuilds server and equipment rooms as engineered spaces: proper racks and cabinets, structured patching, front-to-back airflow, monitored environment, conditioned and backed-up power, and cable management that makes the next change a ten-minute job.

We handle the active side too: switching, routing, firewalls, VLAN and segmentation design, storage, virtualization hosts and backup. We also relocate entire rooms during moves and renovations with a cut plan that minimizes downtime.

Server Solutions installed by Wiscom Services Inc.

Where we deploy it

  • Server rooms & MDF
  • Branch IDF closets
  • Small data centers
  • Office relocations
  • Manufacturing plants
  • Healthcare IT
  • Education districts
  • Disaster recovery sites

Talk to an estimator

Send us drawings, a device count, or just the square footage, and we’ll tell you what the scope realistically looks like.

Capabilities

What this service actually includes.

Not a category heading, but the specific work we self-perform under it.

Rack & room build-out

Open-frame racks and enclosed cabinets, seismic and floor anchoring, ladder rack and overhead pathway, vertical managers, blanking panels and containment so cold air goes through equipment.

Network hardware

Switch stacks, routers, firewalls and wireless controllers installed and configured: VLAN segmentation, trunking, link aggregation, spanning tree, QoS for voice and video, and out-of-band management access.

Storage & virtualization

NAS and SAN deployment, RAID configuration, hypervisor hosts, shared storage networking and capacity planning against real growth rather than a guess.

Backup & recovery

On-site and offsite backup design to a 3-2-1 standard, immutable and air-gapped copies, documented recovery point and recovery time objectives, and restore testing, because an untested backup is a hope, not a plan.

Power & cooling

Rack UPS and managed PDUs, generator coordination, dedicated cooling or supplemental units, and environmental monitoring for temperature, humidity, water and door position with alerting.

Migrations & relocations

Server room moves, consolidations and data center relocations with a labeled cut plan, staged rebuild, after-hours execution and a verified rollback position at every step.

Specification

How we decide what to specify.

The reference table our estimators and engineers work from when scoping this service.

LayerWhat we installWhy it matters
PhysicalRacks, cabinets, pathway, patching, labelingChange becomes routine instead of risky
PowerUPS, PDUs, dedicated circuits, generator tie-inOutages stop taking the business with them
EnvironmentalCooling, monitoring, leak and temp alertsYou hear about a hot room before hardware dies
NetworkSwitching, routing, firewall, segmentationTraffic is fast, isolated and troubleshootable
DataStorage, RAID, virtualization hostsCapacity and performance match the workload
ContinuityBackups, replication, tested restoresA bad day stays a bad day, not a closure

Close-out

What you receive when we’re done.

Documentation is part of the scope, not a favor. Every server solutions project closes out with the same package, so the next person to touch the system, whether that is us or somebody else, can work from facts.

Ask for this list on every bid you receive. A contractor who cannot produce test results and as-builts is asking you to trust that the work was done right.
  • Rack elevation drawings, front and rear
  • Network topology diagram and IP/VLAN schedule
  • Labeled patching with a port-to-port schedule
  • Environmental monitoring with alert recipients configured
  • Documented backup schedule and a witnessed test restore
  • Configuration backups and credentials handed over securely

FAQ

Server Solutions: common questions

Usually most of it can. We stage a new rack and patching alongside the existing one, move circuits in planned groups, and schedule the genuinely disruptive cut-overs after hours. We will be honest about which moves require a maintenance window. Some always will.

Many organizations land in a hybrid. Even in a cloud-first environment you still need switching, firewalls, wireless controllers, local storage for cameras and video, and a solid local network. The room gets smaller; it does not go away.

We test restores. Backup software reporting success only proves a job ran. We perform and document a real restore at commissioning and recommend a recurring test schedule, because the first time you discover a backup is unusable should never be during an incident.

Yes. Environmental sensors for temperature, humidity, water and door position, plus UPS and network device monitoring, can alert your team, ours, or both. We set thresholds that warn early enough to act rather than merely confirming the damage.

Free estimate · No obligation

Let’s scope your project.

Tell us what the building has to do. We’ll walk the site, design the system around it and give you a written estimate with no line items you can’t explain.

  • Site survey before we quote, not after
  • Written scope so you can compare bids honestly
  • One accountable contractor across every low voltage trade
Request a free estimate (470) 420-8885 Email the team

Mon–Fri 9:00am–5:00pm ET · HQ in Doraville, GA · Crews nationwide